Specifications |
COMPOWER CPX MAXI – 60kVA - 200kVA |
![]()
|
|||||||||||
|
|
Features and BenefitsBuilt in batteries for up to 100 kVAComPower Maxi is compatible with a wide range of battery autonomies. Furthermore the ripple-free and temperature controlled battery chargers protect your batteries and extend their life time performance. ComPower Maxi is available with integrated enclosures to accommodate batteries for 60, 80 and 100 kVA power ranges. Front access facilitates installation and service of batteries. High efficiency and minimum cost of ownershipWith a transformerless design and the Energy Saving Inverter Switching (ESIS) Technology, ComPower Maxi delivers high efficiency at partial and rated loads (up to 95.5 %). This level of efficiency reduces dramatically the Total Cost of Ownership of the UPS during its life cycle. In addition to lower operating costs, ComPower Maxi extends battery run times and the life of components. Overall power performance is therefore very much increased. Low input harmonic distortion (THDi)ComPower Maxi is capable of keeping the Total Input Harmonic Distortion (THDi) at a low level (3.5% at 100% load). Thycon’s unique technology neutralizes the emission of harmonics at the input of the UPS, provides greater reliability of operations for circuit breakers and extends the overall life of the equipment. Low harmonic distortions saves unnecessary oversizing of gen-sets, cabling and circuit breakers, avoids extra heating of input transformers and extends the overall life time of all input components. ![]() Near to unity Input power factorThe near to unity input power factor (sinewave) of ComPower Maxi reduces the input installation costs by using smaller cable sections and smaller fuse sizes. Accordingly the use of additional phase compensating devices is not needed which consequently keeps the overall UPS efficiency high. Fully rated output power (Blade Friendly)ComPower Maxi is rated at an output of 0.9 leading and delivers fully rated active power for applications in the wide range of 0.9 leading to 0.73 lagging. In other words ComPower Maxi does not require de-rating within the mentioned range and is fully optimised for a wide range of IT and industrial loads and applications. ![]() Advanced scalable architectureIf additional capacity or redundancy is needed, up to 10 independent UPS units can be mounted in parallel. Correspondingly, a single system of parallel mounted UPS units can deliver a maximum power capacity of up to 2000 kVA. In all parallel configurations, each ComPower Maxi unit operates independently but is securely synchronised with the others. This scalable architecture keeps the purchasing and operating costs of your power protection solutions exceptionally low. As your power requirements grow, the UPS grows with you - thanks to its flexible scalability – even in the most confined spaces. Your benefits are lower capital commitment, cost-effective expansion and minimal space occupancy. ![]() |
||||||||||||
|
|||||||||||||